Sources and references

SOURCES AND REFERENCES

Every clause we quote comes with its source

Vendor warranty terms, support policies and national standards cited elsewhere on this site are collected here. So you can check them yourself — including checking whether we quoted them correctly.

Every link is a public page on the issuing organisation’s own site. Last verified one by one: 8 September 2026. Standard and document numbers are also given as plain text, so you can still find them if a link breaks.


Manufacturer warranty and support policies

H3C

  • H3C Standard Limited Warranty Terms for IT Products (v2.0) (Chinese) Both sentences quoted in question 1 of our FAQ are in this document: installing, removing, reconfiguring or replacing hardware or software without H3C’s permission is grounds for loss of warranty; and a replacement part “may be new or a refurbished unit of equivalent class, function and quality”.
  • Maintenance service terms (Chinese) An index page; contract terms for IT products (servers, storage) and CT products (network equipment) are downloaded separately — select the product line on the page.

IBM

Oracle

Huawei

Lenovo

We hold the PDF of Lenovo’s General Terms and Conditions for Extended Warranty and Technical Services, which states that equipment “installed, repaired or disassembled by service personnel not authorised by Lenovo” is not covered, and that equipment using non-standard expansion components not certified by Lenovo falls outside the service scope.

Its public download address is a temporary object-storage path and is not suitable to cite here long-term. Ask us for the file, or request the current version from Lenovo.


Engineer and service-provider certification schemes

  • H3C Certification (Chinese) The official three-tier scheme: H3CNE (engineer) / H3CSE (senior engineer) / H3CIE (expert), across data centre, intelligent storage and computing tracks.
  • H3C network service qualification standard (Chinese) Star-rated service qualification (one to five stars), tied to the number of certified engineers held. The standard is reissued annually, so cite it without pinning a year.

Chinese national standards

Directly linkable

Given as standard numbers only

We deliberately do not link these two. The issuing sites have been reorganised in recent years and the same document exists at several historical paths, so a link is likely to rot. Search by standard number instead.

  • GB 50174-2017 — Code for design of data centers (current version) Clause 3.1.1 classifies data centres as Grade A, B or C: Grade A is a fault-tolerant system, Grade B a redundant system, Grade C meets basic needs. The familiar “Grade A = 2N, Grade B = N+1” is an engineering-level interpretation, not the text of the code.
  • GB 50462-2015 — Code for construction and acceptance of data centre infrastructure (current version)

Computing-power and energy-efficiency policy

One caution: each of the eight national hubs was approved by its own letter and the PUE limits differ. A blanket claim that “China requires PUE ≤ 1.2” should be checked back to the specific hub and document number.


About this page

Why it exists. With third-party maintenance, the most reasonable doubt a customer has is whether what the supplier says is true. Rather than write more about ourselves, we would rather put the sources on the table — reading them yourself is worth more than hearing it from us.

Three rules we hold ourselves to:

  1. Quote the text, don’t paraphrase it. If you find a quotation that is inaccurate, tell us and we will correct it.
  2. If we cannot find an official public source, we do not write it. Real examples: the tier names of Lenovo’s enterprise service-provider scheme, the tier structure of Huawei’s ICT authorised service centres, and the official names of Huawei’s HCIA/HCIP/HCIE tracks. For each of these we found only second-hand accounts from training companies, with no manufacturer source — so not a word about them appears on this site. Better to say less than to guess.
  3. Links rot. When we find a dead one we update it or convert it to plain text. If you spot one first, we would be glad to hear.