Memory faults come in two kinds: the ones that leave a trace in a log, and the ones that do not.
The first kind gets ignored, because “ECC corrects it” sounds like the problem is already handled. The second is hard to find, because apart from an occasional reboot there is nothing to go on.
Both deserve attention, for different reasons.
1. One DIMM reports errors, the whole channel slows down
Symptom. The system or BMC log reports correctable errors (CE) on one DIMM. Nothing is interrupted and no data is wrong, but overall performance has dropped.
Cause. To maintain stability, the memory controller will downclock the affected channel or disable cross-channel interleaving.
Consequence. One module’s problem costs the bandwidth of an entire channel, sometimes of the whole system. For bandwidth-sensitive workloads — databases, in-memory processing, densely packed virtualization hosts — that loss is directly measurable.
Deciding whether to replace. Watch the rate of increase of the CE count in the BMC log.
- A handful over a month: monitor
- Dozens or hundreds a day and accelerating: replace
ECC correcting errors is not the same as the problem being handled. Sustained correctable errors are usually a precursor to hardware degradation, and the machine is already trading performance for stability.
When replacing, match rank and frequency to the other modules on the same channel. See Why the same model and capacity still won’t fit.
2. Wrong population order, less memory than you installed
Symptom. Eight modules go in and the system reports six. Or the capacity is right and the performance is not.
Cause. Every platform defines a DIMM population order. This is not cosmetic — it is about channel symmetry. Skipping slots breaks the balance the memory controller needs to establish full interleaving.
Consequence:
- Mild: no interleaving, reduced bandwidth, correct capacity — so nobody notices
- Severe: modules not detected at all
What to do. Follow the silkscreen or the service manual. Most boards mark slots A1/B1/C1/D1 or colour-code the priority slots. Do not improvise.
The same applies to single-module replacement. The module goes back into the slot it came out of. Dropping it into a nearby slot because “that one’s empty anyway” is the most common source of this problem.
It raises no error. It just quietly costs performance, and a capacity and frequency audit finds it.
3. No memory errors logged, but the machine reboots every few days
Symptom. No obvious hardware alert, but the system goes down or reboots at irregular intervals with no discernible pattern.
This is the hardest of the three.
Likely cause. An uncorrectable error (UCE). ECC corrects single-bit errors and cannot correct multi-bit errors. When one occurs, the system halts immediately rather than let bad data propagate.
Why it is hard to find. The halt is instantaneous, so the operating system often never writes the log to disk. There is nothing in /var/log — just a clean reboot.
Where to look. The BMC hardware event log (iDRAC, iLO, IMM, XCC — names vary). The BMC runs independently of the operating system, so a halt does not stop it recording. A UCE normally leaves an entry, usually with the DIMM slot.
If the slot is not identified. Work by bisection — remove half, run for a period, and see whether the reboots stop. Slow, but faster than waiting for the next crash to produce better evidence.
Spare parts note. Memory for out-of-warranty platforms is often discontinued. Having one module staged beats sourcing one under pressure — particularly if you are about to bisect, since that requires a module you know is good.
Order of work
| Symptom | Look here first | What tells you |
|---|---|---|
| Performance down, CE logged | BMC CE counters | Rate of increase, not absolute value |
| Capacity or performance wrong | Board population order | Service manual |
| Intermittent crashes, clean OS log | BMC hardware event log | UCE entries and slot |
| Nothing in the BMC either | Bisection | Narrowing by halves |
Two of the three start at the BMC log. If your estate does not yet forward BMC logs into central monitoring, that should be high on the list — it is the one recorder still working when the machine goes down.
On spare parts
Memory interchangeability is finer-grained than drives: speed, rank, organization, RDIMM versus LRDIMM. Any mismatch can make the order useless. Our catalogue records memory down to the PC4-xxxx and xRxx level along with cross-reference part numbers.
DDR4 RDIMMs for common platforms are mostly physically stocked. Search by brand or part number in Parts Lookup.
This describes common failure modes for this class of equipment, not a specific incident at a named site.